Shoe generators tend to make power in short bursts, so a team in South Korea and the US hid an air bladder under the heel.

Today we’re looking at a future where your shoes top up the battery of a health monitor every time you walk across the room. Welcome to FutureProof.

Why footsteps are hard to use as power

Next time you walk somewhere, pay attention to your heels. Each one comes down roughly once a second, takes your whole bodies weight for a moment, then lifts off again. Researchers have spent years trying to catch some of that energy to run small electronics, especially health monitors you wear all day.

Many of those monitors measure blood oxygen, which is how much oxygen your blood is carrying, given as a percentage of the most it could carry. For a healthy person at rest, it normally sits in the mid to high 90s. A monitor like this runs on a small battery, and every time you take it off to charge, the recording stops.

The trouble with footsteps is timing. Many shoe generators built so far use materials that give off a small electric charge when squeezed or rubbed, and they typically make power in a short burst as your foot lands, with little in between. Electronics need a small, steady supply.

Other teams have tried mechanical tricks to stretch each step’s power out for longer. A team led by researchers at KAIST, a science and technology university in South Korea, and Georgia Tech in the US built a version that does it with air, then used it to charge an oxygen monitor worn on the ankle.

How the shoe turns a step into a spin

So what did they build? Under your heel, between the sole and the insole, sits a soft, rubbery air bladder. When your heel comes down, your weight squashes it and pushes the air out through a thin tube. When you lift your foot, the bladder springs back and fills with air again.

The tube runs to a small unit on the back of the shoe, where a nozzle blows the air onto a little rotor with curved blades. It works a bit like blowing on a pinwheel, and like a pinwheel, the rotor keeps turning after the air stops. One puff keeps it spinning for about 1.5 seconds. Your heel comes down about once a second, so the rotor is still turning when the next puff arrives, and a string of quick presses becomes a spin that hardly stops.

The team tested several blade shapes. Flat blades peaked at about 1,000 revolutions per minute, while curved blades passed 2,500, which is more than 40 turns a second. A U-shaped curve spun the fastest and kept going the longest.

The rotor turns six small magnets into a ring of copper wire coils. Moving a magnet past copper wire makes electricity, which is how a bicycle dynamo works, so the spinning rotor produces a small electric current.

That current can’t charge a battery as it is. Its voltage is too low, and it keeps flipping direction, while a battery needs a steady current flowing one way. A small circuit board raises the voltage and turns the current into a one-way flow, and a charging chip then feeds it into a small rechargeable battery at a steady, gentle rate.

That battery runs an oxygen sensor held on the ankle with a Velcro strap. It uses the same basic idea as the clip a nurse puts on your finger, shining red light and infrared light, into the skin and measuring how much comes back. Each heartbeat pushes a little extra blood under the skin, and blood carrying oxygen absorbs the two colors differently from blood that isn’t. Comparing the two gives an oxygen reading, and the rhythm of the beats gives your pulse. The ankle electronics weigh 15 grams with the battery, and the team put them on the ankle because it’s close to the shoe.

So how much power does the shoe make, and can an ankle sensor be trusted while you’re moving?

What happened when people wore it

At 3.5 kilometers an hour, a typical walking pace for an adult, the shoe’s output didn’t die away between steps. Each new puff topped up a rotor that was still turning, so the electricity came out as an almost continuous wave.

The paper judges that power against smart rings, the health trackers worn on a finger, which typically use between 0.4 and 1 milliwatt, plus another 0.2 to 0.3 with blood oxygen tracking switched on. After the circuit board and charger, the shoe delivered about 0.9 milliwatts to its battery on average, which the authors say puts it within the range of low-power wearables. The paper doesn’t say how much its own ankle sensor uses though.

To test the sensor, three people stood on a treadmill for ten minutes, walked for ten, then stood for another ten. They also wore two commercial devices: a monitor on the shoulder as the main reference, and a clip on the big toe.

While they stood, the ankle sensor’s oxygen readings were about a quarter of a point lower than the shoulder monitor on average. Once walking started, each step squeezed the toe, and the toe clip lost its signal about 86% of the time. The ankle sensor kept reading throughout, though its numbers now ran about 2 percentage points lower than the shoulder monitor’s, so where the shoulder read 97%, the ankle would typically show about 95%. Its pulse readings tracked the shoulder monitor closely the whole time.

Then one person wore the whole system through an 8-hour day of normal routine: desk work, reading, chatting, walking between places, and exercise. A finger clip took a 20-second spot check every half hour. The ankle sensor recorded the whole day without losing its signal, and its readings rose and fell with the spot checks.

Overnight, with no walking to charge it, the sensor ran on its battery through six hours of sleep. Its average oxygen reading came within two-thirds of a point of both the shoulder monitor and a finger clip, with all three close to 97%.

What it can and can’t tell us yet

The authors use “self-powered” to mean the shoe charges the battery while you walk, and they say directly that the system isn’t battery-free in every situation. The footsteps top the battery up, and the battery carries the sensor through times like sleep. A version that never needs outside charging is something they say further improvements could make possible.

The paper also doesn’t report how far the battery ran down during the 8-hour day, so it can’t show how much of that day the footsteps paid for. A rough sum, which isn’t in the paper, gives a sense of scale: the 40 milliamp-hour battery holds about 148 milliwatt-hours, so even eight straight hours of walking at 0.9 milliwatts would add about 7, around 5% of a full charge.

The testing is also small. The sensor comparisons used three people, and the full-day and overnight tests describe one wearer. Every comparison was against other sensors, not blood tests, in healthy people whose readings stayed mostly in the 90s, so the study can’t say how the ankle sensor would do when oxygen genuinely drops. The formula that turns its light readings into an oxygen percentage was also borrowed from an earlier study of a patch worn on the chest, not calibrated for the ankle. The authors say they still need larger and more varied groups, including people with a range of skin tones and different shoe sizes, along with clinical testing. Skin tone is a known issue for light-based sensors: the US Food and Drug Administration says pulse oximeters may be less accurate for people with darker skin. Their check that the pump doesn’t change how people walk used video and a pressure-sensing insole, and they describe it as qualitative, meaning they compared the results by eye. They add that the shoe needs to get smaller and lighter to make it more comfortable to wear.

If the shoe shrinks and the results hold up in bigger groups, the clearest use is health monitoring that has to run day and night, with less time off the body for charging. The authors point to sleep, suggesting the ankle readings could help study breathing problems during sleep, though they say that needs testing against proper reference equipment first.

Here are the bits we found interesting

  1. When oxygen levels shifted, the shoulder monitor noticed first, then the ankle sensor, then the toe clip. The team suggests the order comes down to how far each spot is from the heart.

  2. Body weight mattered less than we’d have guessed. In the first measurements, the output didn’t rise in step with body weight, and after people of different weights followed a simple walking routine for the shoe, their outputs came out similar. The team concluded that squashing and refilling the bladder properly matters more than body weight alone.

  3. By the paper’s estimate, the shoe catches on the order of 0.01% to 0.1% of the mechanical energy available from walking, which the authors say is in line with other wearable harvesters. Their case for it rests on how long each step keeps producing power.

That’s the paper, if you want to dig into the data yourself, the full study is linked below. But before you go, here’s one stray fact.